2.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction.

Journal: IEEE transactions on medical imaging
Published Date:

Abstract

Positron Emission Tomography (PET) is an important clinical imaging tool but inevitably introduces radiation exposure to patients and healthcare providers. Reducing the tracer injection dose and eliminating the CT acquisition for attenuation correction can reduce the overall radiation dose, but often results in PET with high noise and bias. Thus, it is desirable to develop 3D methods to translate the non-attenuation-corrected low-dose PET (NAC-LDPET) into attenuation-corrected standard-dose PET (AC-SDPET). Recently, diffusion models have emerged as a new state-of-the-art deep learning method for image-to-image translation, better than traditional CNN-based methods. However, due to the high computation cost and memory burden, it is largely limited to 2D applications. To address these challenges, we developed a novel 2.5D Multi-view Averaging Diffusion Model (MADM) for 3D image-to-image translation with application on NAC-LDPET to AC-SDPET translation. Specifically, MADM employs separate diffusion models for axial, coronal, and sagittal views, whose outputs are averaged in each sampling step to ensure the 3D generation quality from multiple views. To accelerate the 3D sampling process, we also proposed a strategy to use the CNN-based 3D generation as a prior for the diffusion model. Our experimental results on human patient studies suggested that MADM can generate high-quality 3D translation images, outperforming previous CNN-based and Diffusion-based baseline methods. The code is available at https://github.com/tianqic/MADM.

Authors

  • Tianqi Chen
    Department of Emergency Medicine, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhenjiang Province, China.
  • Jun Hou
    School of Social Science, Nanjing Vocational University of Industry Technology, Nanjing, China.
  • Yinchi Zhou
  • Huidong Xie
    School of Chemistry and Chemical Engineering, Division of Laboratory and Equipment Management, Xi'an University of Architecture and Technology Xi'an 710055 Shaanxi China xiehuidong@tsinghua.org.cn.
  • Xiongchao Chen
    Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
  • Qiong Liu
    Medical College, Hubei University of Arts and Science, China; XiangYang Central Hospital, China.
  • Xueqi Guo
    Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
  • Menghua Xia
  • James S Duncan
    Biomedical Engineering, Yale University, New Haven, CT 06511, USA.
  • Chi Liu
  • Bo Zhou
    Department of Neurology, The Third People's Hospital of Yibin, Yibin, China.

Keywords

No keywords available for this article.