Multiclass Arrhythmia Classification Using Multimodal Smartwatch Photoplethysmography Signals Collected in Real-Life Settings.

Journal: IEEE transactions on bio-medical engineering
Published Date:

Abstract

OBJECTIVE: Smartwatches with photoplethysmographic (PPG) sensors are ideal for early atrial fibrillation (AF) detection through continuous monitoring. However, prior deep learning was limited either to controlled environments, to minimize motion artifacts, or to short duration data collection. Additionally, premature atrial/ventricular contractions (PAC/PVC), which often confound AF detection algorithms, remains understudied due to limited datasets. Current state-of-the-art methods achieve only 75% sensitivity for PAC/PVC class on minimally motion artifact corrupted PPG data, despite showing 97% AF detection accuracy. METHODS: We addressed the above limitations using data from the recently completed NIH-funded Pulsewatch clinical trial which collected over two weeks of smartwatch PPG data from 106 subjects. Our computationally efficient 1D bi-directional Gated Recurrent Unit deep learning model incorporated multi-modal inputs (1D PPG, accelerometer, and heart rate data) to classify normal sinus rhythm, AF, and PAC/PVC. RESULTS: Our model achieved an unprecedented 83% sensitivity for PAC/PVC detection while maintaining a high accuracy of 97.31% for AF detection, outperforming the best retrained state-of-the-art model by 20.81% and 2.55%, respectively. It was also 14 times more computationally efficient and 2.7 times faster. Testing on two external PPG datasets collected with a different smartwatch and a fingertip PPG sensor, our model demonstrated better generalizability with macro-averaged AUROC values of 96.22% and 94.17%, respectively. CONCLUSION: A light-weight multimodal input deep learning model can accurately distinguish PAC/PVC from AF, reducing false positive detection of AF. SIGNIFICANCE: Accurate AF and PAC/PVC detection with minimal false positive detection can enhance clinical and public acceptance of smartwatch-based AF monitoring.

Authors

  • Dong Han
    Department of Radiology, Affiliated Hospital of Chengde Medical College, Chengde Hebei, 067000, P.R.China.
  • Jihye Moon
  • Luis R Mercado Diaz
  • Darren Chen
  • Devan Williams
  • Fahimeh Mohagheghian
    Nell Hodgson Woodruff School of Nursing, Emory University, Atlanta, GA, United States of America.
  • Om Ghetia
  • Andrew G Peitzsch
  • Youngsun Kong
    Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut.
  • Nishat Nishita
  • Ohm Ghutadaria
  • Taylor A Orwig
  • Edith Mensah Otabil
  • Kamran Noorishirazi
  • Alexander Hamel
  • Emily L Dickson
  • Danielle DiMezza
  • Darleen Lessard
  • Ziyue Wang
    Mingxu Technology Co., Ltd., Shanghai, China.
  • Tenes Paul
  • Jordy Mehawej
  • Andreas Filippaios
  • Syed Naeem
  • Matthew F Gottbrecht
  • Timothy P Fitzgibbons
  • Jane S Saczynski
  • Bruce Barton
    Departments of Quantitative Health Sciences, University of Massachusetts Medical School, Worcester.
  • Eric Y Ding
  • Khanh-Van Tran
    Division of Cardiology, Department of Medicine, University of Massachusetts Chan Medical School, Worcester, MA 01655, United States.
  • David D McManus
    Department of Medicine, University of Massachusetts Medical School, Worcester, MA, United States.
  • Ki H Chon
    Department of Biomedical Engineering, University of Connecticut, Storrs, CT, United States of America.

Keywords

No keywords available for this article.