Intelligent extraction of CT image landmarks for improving cam-type femoroacetabular impingement assessment.
Journal:
European radiology
Published Date:
Oct 1, 2025
Abstract
OBJECTIVES: Femoroacetabular impingement (FAI) with cam-type morphology is a common hip disorder that can result in groin pain and eventually osteoarthritis. The pre-operative assessment is based on parameters obtained from x-ray or computed tomography (CT) scans, namely alpha angle (AA) and femoral head-neck offset (FHNO). The goal of our study was to develop a computer-aided detection (CAD) system to automatically select the hip region and measure diagnostic parameters from CT scans to overcome the limitations of the tedious and time-consuming process of subjectively selecting CT image slices to obtain parameters. MATERIALS AND METHODS: 271 cases of ordinary abdominopelvic CT examination were collected retrospectively from two hospitals between 2018 and 2022, each equipped with a distinct CT scanner. First, a convolution neural network (CNN) was designed to select hip region slices among abdominopelvic CT scan image series. This CNN was trained using 80 CT scans divided into 50%, 20%, and 30% for training, validation and testing groups, respectively. Second, the most appropriate oblique slice passing through the femoral head-neck complex was selected, and AA and FHNO landmarks were calculated using image-processing algorithms. The best oblique slices were selected/measured manually for each hip as ground truth and its related parameters. RESULTS: CT hip-region selection using CNN yielded 99.34% accuracy. Pearson correlation coefficient between manual and automatic parameters measurement were 0.964 and 0.856 for AA and FHNO, respectively. CONCLUSION: The results of this study are promising for future development of a CAD software application for screening CT scans that may aid physicians to assess FAI. KEY POINTS: Question Femoroacetabular impingement is a common, underdiagnosed hip disorder requiring time-consuming image-based measurements. Can AI improve the efficiency and consistency of its radiologic assessment? Findings Automated slice selection and landmark detection using a hybrid AI method improved measurement efficiency and accuracy, with minimal bias confirmed through Bland-Altman analysis. Clinical relevance An AI-based method enables faster, more consistent evaluation of cam-type femoroacetabular impingement in routine CT images, supporting earlier identification and reducing dependency on operator experience in clinical workflows.
Authors
Keywords
No keywords available for this article.