Reducing image variability across OCT devices with unsupervised unpaired learning for improved segmentation of retina.

Journal: Biomedical optics express
Published Date:

Abstract

Diagnosis and treatment in ophthalmology depend on modern retinal imaging by optical coherence tomography (OCT). The recent staggering results of machine learning in medical imaging have inspired the development of automated segmentation methods to identify and quantify pathological features in OCT scans. These models need to be sensitive to image features defining patterns of interest, while remaining robust to differences in imaging protocols. A dominant factor for such image differences is the type of OCT acquisition device. In this paper, we analyze the ability of recently developed unsupervised unpaired image translations based on cycle consistency losses (cycleGANs) to deal with image variability across different OCT devices (Spectralis and Cirrus). This evaluation was performed on two clinically relevant segmentation tasks in retinal OCT imaging: fluid and photoreceptor layer segmentation. Additionally, a visual Turing test designed to assess the quality of the learned translation models was carried out by a group of 18 participants with different background expertise. Results show that the learned translation models improve the generalization ability of segmentation models to other OCT-vendors/domains not seen during training. Moreover, relationships between model hyper-parameters and the realism as well as the morphological consistency of the generated images could be identified.

Authors

  • David Romo-Bucheli
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Philipp Seeböck
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • José Ignacio Orlando
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Bianca S Gerendas
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Sebastian M Waldstein
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Ursula Schmidt-Erfurth
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.
  • Hrvoje Bogunović
    Christian Doppler Laboratory for Ophthalmic Image Analysis (OPTIMA), Department of Ophthalmology, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.

Keywords

No keywords available for this article.