Correcting and sharing our complications. Misplacement of pigtail catheter, during a Robot Assisted Pyeloplasty. Clinical findings, diagnosis, possible causes and endoscopic treatment.

Journal: Archivio italiano di urologia, andrologia : organo ufficiale [di] Societa italiana di ecografia urologica e nefrologica
PMID:

Abstract

OBJECTIVE: Robotic assisted pyeloplasty (RAP) is rapidly adopted by surgeons around the world. We present a unique complication of the technique, consisting of pigtail misplacement, which was endoscopically resolved. We discuss the clinical findings, differential diagnosis and principles of endoscopic treatment.

Authors

  • Konstantinos Stravodimos
    1st University Urology Clinic, Laiko Hospital. katafigiotis@yahoo.com.
  • Ioannis Katafigiotis
  • Evangelos Fragkiadis
  • Stavros Tyritzis
  • Constantinos A Constantinides