Reduced versus standard dose contrast volume for contrast-enhanced abdominal CT in overweight and obese patients using photon counting detector technology vs. second-generation dual-source energy integrating detector CT.

Journal: European journal of radiology
PMID:

Abstract

PURPOSE: To compare image quality of contrast-enhanced abdominal-CT using 1st-generation Dual Source Photon-Counting Detector CT (DS-PCD-CT) versus 2nd-generation Dual-Source Energy Integrating-Detector CT (DS-EID-CT) in patients with BMI ≥ 25, applying two different contrast agent volumes, vendor proposed protocols and different virtual monoenergetic images (VMI).

Authors

  • Florian Hagen
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
  • Arne Estler
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
  • Johannes Hofmann
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
  • Lukas Walder
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
  • Sebastian Faby
    Siemens Healthcare GmbH, Forchheim, Germany.
  • Bassel Almarie
    Neuromodulation Center and Center for Clinical Research Learning, Spaulding Rehabilitation Hospital, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.
  • Konstantin Nikolaou
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
  • Robin Wrazidlo
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany.
  • Marius Horger
    Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Str.3, 72076 Tübingen, Germany. Electronic address: marius.horger@med.uni-tuebingen.de.