Deep Learning Using Multiple Degrees of Maximum-Intensity Projection for PET/CT Image Classification in Breast Cancer.

Journal: Tomography (Ann Arbor, Mich.)
Published Date:

Abstract

Deep learning (DL) has become a remarkably powerful tool for image processing recently. However, the usefulness of DL in positron emission tomography (PET)/computed tomography (CT) for breast cancer (BC) has been insufficiently studied. This study investigated whether a DL model using images with multiple degrees of PET maximum-intensity projection (MIP) images contributes to increase diagnostic accuracy for PET/CT image classification in BC. We retrospectively gathered 400 images of 200 BC and 200 non-BC patients for training data. For each image, we obtained PET MIP images with four different degrees (0°, 30°, 60°, 90°) and made two DL models using Xception. One DL model diagnosed BC with only 0-degree MIP and the other used four different degrees. After training phases, our DL models analyzed test data including 50 BC and 50 non-BC patients. Five radiologists interpreted these test data. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated. Our 4-degree model, 0-degree model, and radiologists had a sensitivity of 96%, 82%, and 80-98% and a specificity of 80%, 88%, and 76-92%, respectively. Our 4-degree model had equal or better diagnostic performance compared with that of the radiologists (AUC = 0.936 and 0.872-0.967, = 0.036-0.405). A DL model similar to our 4-degree model may lead to help radiologists in their diagnostic work in the future.

Authors

  • Kanae Takahashi
    Department of Medical Statistics, Osaka City University Graduate School of Medicine, Osaka, Japan.
  • Tomoyuki Fujioka
    Department of Diagnostic Radiology, Tokyo Medical and Dental University Hospital, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8501, Japan.
  • Jun Oyama
    Department of Diagnostic Radiology, Tokyo Medical and Dental University, Tokyo, Japan.
  • Mio Mori
    Department of Diagnostic Radiology, Tokyo Medical and Dental University Hospital, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8501, Japan.
  • Emi Yamaga
    Department of Diagnostic Radiology, Tokyo Medical and Dental University Hospital, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8501, Japan.
  • Yuka Yashima
    Department of Radiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minami-koshigaya, Koshigaya 343-8555, Japan.
  • Tomoki Imokawa
    Department of Diagnostic Radiology, Tokyo Medical and Dental University, Bunkyo Ku, Tokyo, Japan.
  • Atsushi Hayashi
    Department of Radiology, Tokyo Medical and Dental University, Tokyo 113-8510, Japan.
  • Yu Kujiraoka
    Department of Radiology, Tokyo Medical and Dental University, Tokyo 113-8510, Japan.
  • Junichi Tsuchiya
    Department of Radiology, Tokyo Medical and Dental University, Tokyo 113-8510, Japan.
  • Goshi Oda
    Department of Surgery, Breast Surgery, Tokyo Medical and Dental University Hospital, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8501, Japan.
  • Tsuyoshi Nakagawa
    Department of Surgery, Breast Surgery, Tokyo Medical and Dental University Hospital, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8501, Japan.
  • Ukihide Tateishi
    Department of Diagnostic Radiology, Tokyo Medical and Dental University Hospital, 1-5-45, Yushima, Bunkyo-ku, Tokyo 113-8501, Japan.