A Flexible Pressure Sensor Based on Silicon Nanomembrane.

Journal: Biosensors
Published Date:

Abstract

With advances in new materials and technologies, there has been increasing research focused on flexible sensors. However, in most flexible pressure sensors made using new materials, it is challenging to achieve high detection sensitivity across a wide pressure range. Although traditional silicon-based sensors have good performance, they are not formable and, because of their rigidity and brittleness, they are not suitable for fitting with soft human skin, which limits their application in wearable devices to collect various signals. Silicon nanomembranes are ultra-thin, flexible materials with excellent piezoresistive properties, and they can be applied in various fields, such as in soft robots and flexible devices. In this study, we developed a flexible pressure sensor based on the use of silicon nanomembranes (with a thickness of only 340 nm) as piezoresistive units, which were transferred onto a flexible polydimethylsiloxane (PDMS) substrate. The flexible pressure sensor operated normally in the range of 0-200 kPa, and the sensitivity of the sensor reached 0.0185 kPa in the low-pressure range of 0-5 kPa. In the high-pressure range of 5-200 kPa, the sensitivity of the sensor was maintained at 0.0023 kPa. The proposed sensor exhibited a fast response and excellent long-term stability and could recognize human movements, such as the bending of fingers and wrist joints, while maintaining a stable output. Thus, the developed flexible pressure sensor has promising applications in body monitoring and wearable devices.

Authors

  • Lixia Cheng
    State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China.
  • Xiaojian Hao
    State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China.
  • Guochang Liu
    State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China.
  • Wendong Zhang
    School of Instrument and Electronics, Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan, China.
  • Jiangong Cui
    State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China.
  • Guojun Zhang
    The department of Respiratory Medicine of The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, 450052, China. Electronic address: zlgj-001@126.com.
  • Yuhua Yang
    State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China.
  • Renxin Wang
    State Key Laboratory of Dynamic Testing Technology, North University of China, Taiyuan 030051, China.