Deep learning based automatic contour refinement for inaccurate auto-segmentation in MR-guided adaptive radiotherapy.

Journal: Physics in medicine and biology
Published Date:

Abstract

Fast and accurate auto-segmentation is essential for magnetic resonance-guided adaptive radiation therapy (MRgART). Deep learning auto-segmentation (DLAS) is not always clinically acceptable, particularly for complex abdominal organs. We previously reported an automatic contour refinement (ACR) solution of using an active contour model (ACM) to partially correct the DLAS contours. This study aims to develop a DL-based ACR model to work in conjunction with ACM-ACR to further improve the contour accuracy.The DL-ACR model was trained and tested using bowel contours created by an in-house DLAS system from 160 MR sets (76 from MR-simulation and 84 from MR-Linac). The contours were classified into acceptable, minor-error and major-error groups using two approaches of contour quality classification (CQC), based on the AAPM TG-132 recommendation and an in-house classification model, respectively. For the major-error group, DL-ACR was applied subsequently after ACM-ACR to further refine the contours. For the minor-error group, contours were directly corrected by DL-ACR without applying an initial ACM-ACR. The ACR workflow was performed separately for the two CQC methods and was evaluated using contours from 25 image sets as independent testing data.The best ACR performance was observed in the MR-simulation testing set using CQC by TG-132: (1) for the major-error group, 44% (177/401) were improved to minor-error group and 5% (22/401) became acceptable by applying ACM-ACR; among these 177 contours that shifted from major-error to minor-error with ACM-ACR, DL-ACR further refined 49% (87/177) to acceptable; and overall, 36% (145/401) were improved to minor-error contours, and 30% (119/401) became acceptable after sequentially applying ACM-ACR and DL-ACR; (2) for the minor-error group, 43% (320/750) were improved to acceptable contours using DL-ACR.The obtained ACR workflow substantially improves the accuracy of DLAS bowel contours, minimizing the manual editing time and accelerating the segmentation process of MRgART.

Authors

  • Jie Ding
    State Key Laboratory of Respiratory Disease, Joint School of Life Sciences, Guangzhou Chest Hospital, Guangzhou Institutes of Biomedicine and Health, Chinese Academy of Sciences, Guangzhou Medical University, Guangzhou, China.
  • Ying Zhang
    Department of Nephrology, Nanchong Central Hospital Affiliated to North Sichuan Medical College, Nanchong, China.
  • Asma Amjad
    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
  • Christina Sarosiek
    Department of Radiation Oncology, Medical College of Wisconsin, United States of America.
  • Nguyen Phuong Dang
    Department of Radiation Oncology, Medical College of Wisconsin, United States of America.
  • Mohammad Zarenia
    Department of Radiation Oncology, Medical College of Wisconsin, United States of America.
  • X Allen Li
    Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.