Robust vessel segmentation in laser speckle contrast images based on semi-weakly supervised learning.

Journal: Physics in medicine and biology
Published Date:

Abstract

The goal of this study is to develop a robust semi-weakly supervised learning strategy for vessel segmentation in laser speckle contrast imaging (LSCI), addressing the challenges associated with the low signal-to-noise ratio, small vessel size, and irregular vascular aberration in diseased regions, while improving the performance and robustness of the segmentation method.For the training dataset, the healthy vascular images denoted as normal-vessel samples were manually labeled, while the diseased LSCI images involving tumor or embolism were denoted as abnormal-vessel samples and annotated as pseudo labels by the traditional semantic segmentation methods. In the training phase, the pseudo labels were constantly updated to improve the segmentation accuracy based on DeepLabv3+. Objective evaluation was conducted on the normal-vessel test set, while subjective evaluation was performed on the abnormal-vessel test set.The proposed method achieved an IOU of 0.8671, a Dice of 0.9288, and a mean relative percentage difference (mRPD) with supervised learning of 0.5% in the objective evaluation. In the subjective evaluation, our method significantly outperformed other methods in main vessel segmentation, tiny vessel segmentation, and blood vessel connection. Additionally, our method exhibited robustness when abnormal-vessel style noise was added to normal-vessel samples using a style translation network.The proposed semi-weakly supervised learning strategy demonstrates high efficiency and excellent robustness for vascular segmentation in LSCI, providing a potential tool for assessing the morphological and structural features of vessels in clinical applications.

Authors

  • Kun Yang
    Department of Bone and Joint Surgery, Affiliated Hospital of Southwest Medical University, Luzhou Sichuan, 646000, P.R.China.
  • Shilong Chang
    College of Quality and Technical Supervision, Hebei University, Baoding 071002, Hebei, China.
  • Jiacheng Yuan
    College of Quality and Technical Supervision, Hebei University, Baoding 071002, People's Republic of China.
  • Suzhong Fu
    Center for Molecular Imaging and Translational Medicine, Department of Laboratory Medicine, School of Public Health, Xiamen University, Xiamen 361102, People's Republic of China.
  • Geng Qin
    College of Quality and Technical Supervision, Hebei University, Baoding 071002, People's Republic of China.
  • Shuang Liu
    Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Shandong Analysis and Test Center, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250014, China.
  • Kun Liu
    Department of Anesthesiology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai 200030, China.
  • Qingliang Zhao
    Center for Molecular Imaging and Translational Medicine, Department of Laboratory Medicine, School of Public Health, Xiamen University, Xiamen 361102, People's Republic of China.
  • Linyan Xue
    School of Quality and Technical Supervision, Hebei University, Baoding, Hebei 071002, P.R.China.