Quantification of L-lactic acid in human plasma samples using Ni-based electrodes and machine learning approach.

Journal: Talanta
PMID:

Abstract

This work presents a robust strategy for quantifying overlapping electrochemical signatures originating from complex mixtures and real human plasma samples using nickel-based electrochemical sensors and machine learning (ML). This strategy enables the detection of a panel of analytes without being limited by the selectivity of the transducer material and leaving accommodation of interference analysis to ML models. Here, we fabricated a non-enzymatic electrochemical sensor for L-lactic acid detection in complex mixtures and human plasma samples using nickel oxide (NiO) nanoparticle-modified glassy carbon electrodes (GCE). This paper presents a data-driven approach for developing transducers that reduce interference effects using ML with a sufficiently large dataset. The interference trends of uric acid, ascorbic acid, and glucose were measured in the presence of L-lactic acid and the complex data set was analyzed using various ML models. Limit of detections of 2.61 μM, 15.99 μM, 11.34 μM, and 3.27 μM for L-lactic acid, uric acid, glucose, and ascorbic acid were obtained, respectively, in a complex mixture using an artificial neural network-based-regression model. Further, the electrochemical signature was recorded for 10 different human plasma samples and analyzed using developed ML models to validate the sensor performance in real samples. The random forest model performance was tested against the L-lactic acid levels in human plasma samples obtained through conventional colorimetric assays which showed a good prediction performance with coefficient of determination (R), limit of detection (LOD), and limit of quantitation (LOQ) values of 0.99, 1.3 μM, and 4.4 μM respectively. By further miniaturization and integration of such sensors into point-of-care testing devices, metabolic profiles of different redox-active species related to the measurement of the predictive value of sepsis can be managed.

Authors

  • Brateen Datta
    NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, West Bengal, 721302, India.
  • Basavaprabhu Manasur
    NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, West Bengal, 721302, India.
  • Gajje Sreelekha
    Dept. of CSE, Indian Institute of Technology Patna, Bihar, 801106, India.
  • Poornima Verma
    Dept. of CSE, Indian Institute of Information Technology Lucknow, Uttar Pradesh, 226002, India.
  • Chandranath Adak
    Dept. of CSE, Indian Institute of Technology Patna, Bihar, 801106, India. Electronic address: chandranath@iitp.ac.in.
  • Rajendra P Shukla
    Department of Electrical and Computer Engineering, North Carolina State University, 890 Oval Dr., Raleigh, NC 27695, USA. Electronic address: rshukla4@ncsu.edu.
  • Gorachand Dutta
    NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, West Bengal, 721302, India. Electronic address: g.dutta@smst.iitkgp.ac.in.