Learning ECOC Code Matrix for Multiclass Classification with Application to Glaucoma Diagnosis.

Journal: Journal of medical systems
PMID:

Abstract

Classification of different mechanisms of angle closure glaucoma (ACG) is important for medical diagnosis. Error-correcting output code (ECOC) is an effective approach for multiclass classification. In this study, we propose a new ensemble learning method based on ECOC with application to classification of four ACG mechanisms. The dichotomizers in ECOC are first optimized individually to increase their accuracy and diversity (or interdependence) which is beneficial to the ECOC framework. Specifically, the best feature set is determined for each possible dichotomizer and a wrapper approach is applied to evaluate the classification accuracy of each dichotomizer on the training dataset using cross-validation. The separability of the ECOC codes is maximized by selecting a set of competitive dichotomizers according to a new criterion, in which a regularization term is introduced in consideration of the binary classification performance of each selected dichotomizer. The proposed method is experimentally applied for classifying four ACG mechanisms. The eye images of 152 glaucoma patients are collected by using anterior segment optical coherence tomography (AS-OCT) and then segmented, from which 84 features are extracted. The weighted average classification accuracy of the proposed method is 87.65 % based on the results of leave-one-out cross-validation (LOOCV), which is much better than that of the other existing ECOC methods. The proposed method achieves accurate classification of four ACG mechanisms which is promising to be applied in diagnosis of glaucoma.

Authors

  • Xiaolong Bai
    State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou, 310027, People's Republic of China. bxl@zju.edu.cn.
  • Swamidoss Issac Niwas
    School of Electrical and Electronics Engineering & School of Computer Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore. issacniwas@ntu.edu.sg.
  • Weisi Lin
  • Bing-Feng Ju
    State Key Laboratory of Fluid Power Transmission and Control, Zhejiang University, Hangzhou, 310027, People's Republic of China. mbfju@zju.edu.cn.
  • Chee Keong Kwoh
    School of Computer Science and Engineering,  Nanyang  Technological  University,  50  Nanyang  Avenue,  639798, Singapore.
  • Lipo Wang
    School of Electrical and Electronics Engineering, Nanyang Technological University (NTU), Singapore, 639798, Singapore. elpwang@ntu.edu.sg.
  • Chelvin C Sng
    Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore (NUS), Singapore, 119228, Singapore. chelvin@gmail.com.
  • Maria C Aquino
    Eye Surgery Centre, National University Health System (NUHS), Singapore, 119228, Singapore. mcdaquino@gmail.com.
  • Paul T K Chew
    Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore (NUS), Singapore, 119228, Singapore. ophchewp@nus.edu.sg.