Ag+ modified paper-based SERS combined with SiPLS for quantitative detection of soluble As3+ in aqueous realgar solutions.

Journal: Analytica chimica acta
Published Date:

Abstract

The detection of soluble arsenic in realgar and its preparations is crucial for toxicity evaluation. Therefore, surface-enhanced Raman spectroscopy (SERS) combined with machine learning was applied for the rapid detection of soluble As3+ in realgar and realgar-containing preparations. The substrate was prepared via interfacial self-assembly of silver nanoparticles and modified with Ag + to enhance arsenic adsorption and improve detection sensitivity. Quantitative models were constructed based on the analysis of As3+ standard solutions ranging from 10 to 1000 ppb, utilizing five different chemometric methods. Amongst the algorithms, the SiPLS model produced a lower Root Mean Square Error (RMSE) of 9.125 and a coefficient of determination (R2) of 0.999, indicating a more accurate fit between predicted and measured values. Based on the established model, the leaching concentrations of As3+ were determined in realgar and four realgar-containing preparations (Children's Qizhen Pills, Children's Qiying Pills, Children's Huadu Powder, and Liushen Pills) after 12 h of aqueous immersion. The mean As3+ concentrations from three batches of realgar were 862, 948, and 807 ppb, with relative standard deviations (RSDs) of 4.9 %, 5.2 %, and 5.1 %, respectively. For the four prepasrations, the As3+ concentrations were 138, 96, 86, and 117 ppb, with RSDs of 7.1 %, 6.2 %, 8.3 %, and 8.5 %, respectively. This method is rapid, accurate, non-destructive, and easy to implement, showing potential for quantitative analysis and quality control of soluble arsenic in realgar and related formulations.

Authors

  • Kai Hu
    State Key Laboratory of Information Engineering in Surveying, Mapping and Remote Sensing, Wuhan University, Wuhan, China.
  • Guoqiang Fang
    National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150080, China; Zhengzhou Research Institute, Harbin Institute of Technology, Zhengzhou 450018, China.
  • Wuliji Hasi
    National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, 150080, China. [email protected].
  • Siqingaowa Han
    Department of Combination of Mongolian Medicine and Western Medicine Stomatology, Affiliated Hospital of Inner Mongolia University for the Nationalities, Tongliao, 028043, China.