[Determination of 32 polychlorinated biphenyls in aquatic products by gas chromatography-high-resolution mass spectrometry with accelerated solvent extraction-purification simultaneously coupled to isotope internal standard method].

Journal: Se pu = Chinese journal of chromatography
Published Date:

Abstract

Gas chromatography (GC)-high-resolution mass spectrometry (HRMS) with accelerated solvent extraction (ASE)-purification simultaneously coupled to the isotope internal standard method is proposed for the determination of 32 polychlorinated biphenyls (PCBs) in aquatic products. Synchronous purification was achieved by adding 2 g of anhydrous sodium sulfate, 1 g of Cleanert Florisil, and 50 g of neutral alumina as the adsorbent to the ASE system. The PCBs were extracted from aquatic product samples using a dichloromethane--hexane (1:1, v/v) mixture at 100 ℃ with two extraction cycles. The extracting solution was purified twice with 0.5 mL concentrated sulfuric acid. After concentration to a constant volume, the target compounds were detected by GC-HRMS and quantified by the isotope internal standard method. Under the optimized conditions, the relative standard deviations (RSDs) of the mean relative response factor (RRF) for the 32 PCBs in the range of 0.1-20 μg/L were less than 15%. The limits of quantification were 0.3-1.9 ng/kg. At three spiked levels (5, 20, and 50 ng/kg) in grass carp and sea bass, the recoveries of the 32 PCBs were between 71.9% and 119.0%, with the RSDs varying from 3.5% to 19.6%. This method effectively reduces the matrix interference and shows high sensitivity, good reproducibility, and stable recovery, thus proving useful for the detection of PCBs in aquatic products.

Authors

  • Feng Jiang
    Hospital of Minzu University of China, Beijing 100081, China.
  • Tingting Yu
    Hubei Provincial Institute for Food Supervision and Test, Hubei Provincial Engineering and Technology Research Center for Food Quality and Safety Test, Wuhan 430075, China.
  • Min Li
    Hubei Provincial Institute for Food Supervision and Test, Hubei Provincial Engineering and Technology Research Center for Food Quality and Safety Test, Wuhan 430075, China.
  • Mao Rong
    Hubei Provincial Institute for Food Supervision and Test, Hubei Provincial Engineering and Technology Research Center for Food Quality and Safety Test, Wuhan 430075, China.
  • Li Han
    Hubei Provincial Institute for Food Supervision and Test, Hubei Provincial Engineering and Technology Research Center for Food Quality and Safety Test, Wuhan 430075, China.
  • Zhe Song
    Hubei Provincial Institute for Food Supervision and Test, Hubei Provincial Engineering and Technology Research Center for Food Quality and Safety Test, Wuhan 430075, China.
  • Xiaoling Zhu
    Hubei Provincial Institute for Food Supervision and Test, Hubei Provincial Engineering and Technology Research Center for Food Quality and Safety Test, Wuhan 430075, China.