End-systole and end-diastole detection in short axis cine MRI using a fully convolutional neural network with dilated convolutions.

Journal: Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
Published Date:

Abstract

The correct assessment and characterization of heart anatomy and functionality is usually done through inspection of magnetic resonance image cine sequences. In the clinical setting it is especially important to determine the state of the left ventricle. This requires the measurement of its volume in the end-diastolic and end-systolic frames within the sequence trough segmentation methods. However, the first step required for this analysis before any segmentation is the detection of the end-systolic and end-diastolic frames within the image acquisition. In this work we present a fully convolutional neural network that makes use of dilated convolutions to encode and process the temporal information of the sequences in contrast to the more widespread use of recurrent networks that are usually employed for problems involving temporal information. We trained the network in two different settings employing different loss functions to train the network: the classical weighted cross-entropy, and the weighted Dice loss. We had access to a database comprising a total of 397 cases. Out of this dataset we used 98 cases as test set to validate our network performance. The final classification on the test set yielded a mean frame distance of 0 for the end-diastolic frame (i.e.: the selected frame was the correct one in all images of the test set) and 1.242 (relative frame distance of 0.036) for the end-systolic frame employing the optimum setting, which involved training the neural network with the Dice loss. Our neural network is capable of classifying each frame and enables the detection of the end-systolic and end-diastolic frames in short axis cine MRI sequences with high accuracy.

Authors

  • Manuel Pérez-Pelegrí
    Center for Biomaterials and Tissue Engineering, Universitat Politècnica de València, Camí de Vera, s/n, 46022 Valencia, Spain.
  • José V Monmeneu
    Unidad de Imagen Cardíaca, ERESA-ASCIRES Grupo Biomédico, Valencia, Spain.
  • María P López-Lereu
    Unidad de Imagen Cardíaca, ERESA-ASCIRES Grupo Biomédico, Valencia, Spain.
  • Alicia M Maceira
    Unidad de Imagen Cardíaca, ERESA-ASCIRES Grupo Biomédico, Valencia, Spain.
  • Vicente Bodí
    Departamento de Medicina, Universitat de València, Estudi General, Valencia, Spain; Servicio de Cardiología, Hospital Clínico Universitario de Valencia, INCLIVA, CIBERCV, Valencia, Spain.
  • David Moratal
    Centre for Biomaterials and Tissue Engineering, Universitat Politècnica de València, Valencia, Spain.