A Deep Learning-based Method to Extract Lumen and Media-Adventitia in Intravascular Ultrasound Images.

Journal: Ultrasonic imaging
Published Date:

Abstract

Intravascular ultrasound (IVUS) imaging allows direct visualization of the coronary vessel wall and is suitable for assessing atherosclerosis and the degree of stenosis. Accurate segmentation and lumen and median-adventitia (MA) measurements from IVUS are essential for such a successful clinical evaluation. However, current automated segmentation by commercial software relies on manual corrections, which is time-consuming and user-dependent. We aim to develop a deep learning-based method using an encoder-decoder deep architecture to automatically and accurately extract both lumen and MA border. Inspired by the dual-path design of the state-of-the-art model IVUS-Net, our method named IVUS-U-Net++ achieved an extension of the U-Net++ model. More specifically, a feature pyramid network was added to the U-Net++ model, enabling the utilization of feature maps at different scales. Following the segmentation, the Pearson correlation and Bland-Altman analyses were performed to evaluate the correlations of 12 clinical parameters measured from our segmentation results and the ground truth. A dataset with 1746 IVUS images from 18 patients was used for training and testing. Our segmentation model at the patient level achieved a Jaccard measure (JM) of 0.9080 ± 0.0321 and a Hausdorff distance (HD) of 0.1484 ± 0.1584 mm for the lumen border; it achieved a JM of 0.9199 ± 0.0370 and an HD of 0.1781 ± 0.1906 mm for the MA border. The 12 clinical parameters measured from our segmentation results agreed well with those from the ground truth (all -values are smaller than .01). Our proposed method shows great promise for its clinical use in IVUS segmentation.

Authors

  • Fubao Zhu
    School of Computer and Communication Engineering, Zhengzhou University of Light Industry, Zhengzhou, Henan, China.
  • Zhengyuan Gao
    School of Computer and Communication Engineering, Zhengzhou University of Light Industry, Zhengzhou, Henan, China.
  • Chen Zhao
    Department of Ophthalmology, Fudan Eye & ENT Hospital, Shanghai, China.
  • Hanlei Zhu
    School of Computer and Communication Engineering, Zhengzhou University of Light Industry, Zhengzhou, Henan, China.
  • Jiaofen Nan
    School of Computer and Communication Engineering, Zhengzhou University of Light Industry, Zhengzhou, Henan, China.
  • Yanhui Tian
    College of Orthopedics and Traumatology, Henan University of Chinese Medicine, Zhengzhou, China.
  • Yong Dong
    Department of Cardiology, The 7th People's Hospital of Zhengzhou, Zhengzhou, Henan, China.
  • Jingfeng Jiang
    Depts. of Biomedical Engineering, Mechanical Engineering and Engineering Mechanics, and Computer Science, Michigan Technological University, 1400 Townsend Drive Houghton, Michigan 49931, USA.
  • Xiaohong Feng
    Department of Pediatrics, Yicheng Maternity and Child Health Care Hospital, Yicheng, Hubei, China.
  • Neng Dai
    Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai, China.
  • Weihua Zhou
    School of Computing, University of Southern Mississippi, Hattiesburg, MS, United States of America.