Simultaneous determination of Vitamin A, 25-hydroxyl vitamin D α-tocopherol in small biological fluids by liquid chromatography-tandem mass spectrometry.

Journal: Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
PMID:

Abstract

A sensitive method for the simultaneous analysis of vitamin A (VA), 25-hydroxyl vitamin D (25-OH VD) and α-tocopherol (VE) in children plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated. Sample preparation chose the solid phase extraction. 100 μL of plasma was mixed with 300 μL ethanol contained 4 μL isotope-labelled analytes. After a series operation, the supernatant was applied to the solid phase extraction (SPE) plate (HLB μElution plate). The eluate was evaporated, and reconstituted in 100 μL methanol. And then, 6 μL reconstituted sample was injected into LC-MS/MS. Quantitative analysis was carried out by multiple reaction monitoring (MRM) with a positive mode electrospray (ESi + ). Separations of VA, 25-OH VD and VE were performed on an Acquity UPLC reversed-phase Phenyl-Hexyl analytical column (CSH, 2.1 × 50 mm, 1.7 μm). Gradient elution was used at a flow rate of 0.4 mL/min with a mobile phase consisting of 0.1% formic acid solution and 0.1% formic acid, 5 mM ammonium formate in acetonitrile. The total time of analysis was 10 min. The method had a limit of quantification (LOQ) of 10.03, 1.20, and 0.04 ng/mL for VA, 25-OH VD and VE in methanol, respectively. The linear calibration curves were fitted over the range of 0.14-14.32 μg/mL, 1.80-180.29 ng/mL, and 6.03-602.99 ng/mL for VA, 25-OH VD and VE in methanol. The correlation coefficients were greater than 0.998 for all analytes. The recoveries for all analytes were between 80 and 120% with the inter- and intra-day precisions (presented as relative standard deviation, RSD%) less than 10.0%. Analysis of VA, 25-OH VD and VE in recurrent respiratory tract infection children plasma and anemic infants' fingertip blood was then carried out using this method and statistical analysis of the data with statistic package for social science 20.0 (SPSS 20.0). Using this method, multiple fat-soluble vitamins could be detected at the same time. Solid phase extraction was used to simplify sample pretreatment. μElution plate used here could reduce the sample volume, only 100 μL sample was used in this method, and 6 μL reconstituted sample was injected into LC-MS/MS. This makes the method appropriate for larger sample pretreatment, and suitable for children, especially infants and newborns' sample detection, in whom the circulation blood was low.

Authors

  • Haifeng Zhang
    Beijing Municipal Key Laboratory of Child Development and Nutriomics, Capital Institute of Pediatrics, Beijing 100020, China.
  • Li Quan
    Beijing Municipal Key Laboratory of Child Development and Nutriomics, Capital Institute of Pediatrics, Beijing 100020, China; Institute of Molecular Medicine, Peking University, Beijing 100871, China. Electronic address: li_quan@pku.edu.cn.
  • Pei Pei
    Beijing Municipal Key Laboratory of Child Development and Nutriomics, Capital Institute of Pediatrics, Beijing 100020, China.
  • Ye Lin
    Peking Union Medical Collage, Beijing 100730, China.
  • Chao Feng
    Institute of Urology and Nephrology, The First Affiliated Hospital of Guangxi Medical University, Nanning, China.
  • Hongyan Guan
    Beijing Municipal Key Laboratory of Child Development and Nutriomics, Capital Institute of Pediatrics, Beijing 100020, China.
  • Fang Wang
    Key Laboratory of Intelligent Computing and Information Processing of Ministry of Education and Hunan Key Laboratory for Computation and Simulation in Science and Engineering, Xiangtan University, Xiangtan, China.
  • Ting Zhang
    Beijing Municipal Key Laboratory of Child Development and Nutriomics, Capital Institute of Pediatrics, Beijing 100020, China.
  • Jianxin Wu
    Department of Biochemistry, Capital Institute of Pediatrics, Beijing 100020, China. Electronic address: jianxinwu_2000@163.com.
  • Junsheng Huo
    National Institute for Nutrition and Health, Chinese Center for Disease Control and Prevention, Beijing 100050, China.