Deep Learning for Diagnosis of Chronic Myocardial Infarction on Nonenhanced Cardiac Cine MRI.

Journal: Radiology
Published Date:

Abstract

Background Renal impairment is common in patients with coronary artery disease and, if severe, late gadolinium enhancement (LGE) imaging for myocardial infarction (MI) evaluation cannot be performed. Purpose To develop a fully automatic framework for chronic MI delineation via deep learning on non-contrast material-enhanced cardiac cine MRI. Materials and Methods In this retrospective single-center study, a deep learning model was developed to extract motion features from the left ventricle and delineate MI regions on nonenhanced cardiac cine MRI collected between October 2015 and March 2017. Patients with chronic MI, as well as healthy control patients, had both nonenhanced cardiac cine (25 phases per cardiac cycle) and LGE MRI examinations. Eighty percent of MRI examinations were used for the training data set and 20% for the independent testing data set. Chronic MI regions on LGE MRI were defined as ground truth. Diagnostic performance was assessed by analysis of the area under the receiver operating characteristic curve (AUC). MI area and MI area percentage from nonenhanced cardiac cine and LGE MRI were compared by using the Pearson correlation, paired test, and Bland-Altman analysis. Results Study participants included 212 patients with chronic MI (men, 171; age, 57.2 years ± 12.5) and 87 healthy control patients (men, 42; age, 43.3 years ± 15.5). Using the full cardiac cine MRI, the per-segment sensitivity and specificity for detecting chronic MI in the independent test set was 89.8% and 99.1%, respectively, with an AUC of 0.94. There were no differences between nonenhanced cardiac cine and LGE MRI analyses in number of MI segments (114 vs 127, respectively; = .38), per-patient MI area (6.2 cm ± 2.8 vs 5.5 cm ± 2.3, respectively; = .27; correlation coefficient, = 0.88), and MI area percentage (21.5% ± 17.3 vs 18.5% ± 15.4; = .17; correlation coefficient, = 0.89). Conclusion The proposed deep learning framework on nonenhanced cardiac cine MRI enables the confirmation (presence), detection (position), and delineation (transmurality and size) of chronic myocardial infarction. However, future larger-scale multicenter studies are required for a full validation. Published under a CC BY 4.0 license. See also the editorial by Leiner in this issue.

Authors

  • Nan Zhang
    Department of Pulmonary and Critical Care Medicine II, Emergency General Hospital, Beijing, China.
  • Guang Yang
    National Heart and Lung Institute, Imperial College London, London, UK.
  • Zhifan Gao
    School of Biomedical Engineering, Sun Yat-sen University, Shenzhen, China.
  • Chenchu Xu
    From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 2nd Anzhen Road, Chaoyang District, Beijing, China (N.Z., L.X., Z.F.); Cardiovascular Research Centre, Royal Brompton Hospital, London, England (G.Y., R.S., J.K., D.F.); National Heart and Lung Institute, Imperial College London, London, England (G.Y., R.S., J.K., D.F.); Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China (Z.G., H.Z.); Anhui University, Hefei, China (C.X., Y.Z.); and School of Biomedical Engineering, Sun Yat-Sen University, Shenzhen, China (H.Z.).
  • Yanping Zhang
    Key Laboratory of Intelligent Computing and Signal Processing of Ministry of Education, ‡School of Computer Science and Technology, and §Center of Information Support & Assurance Technology, Anhui University , Hefei, 230601 Anhui, China.
  • Rui Shi
    From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 2nd Anzhen Road, Chaoyang District, Beijing, China (N.Z., L.X., Z.F.); Cardiovascular Research Centre, Royal Brompton Hospital, London, England (G.Y., R.S., J.K., D.F.); National Heart and Lung Institute, Imperial College London, London, England (G.Y., R.S., J.K., D.F.); Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China (Z.G., H.Z.); Anhui University, Hefei, China (C.X., Y.Z.); and School of Biomedical Engineering, Sun Yat-Sen University, Shenzhen, China (H.Z.).
  • Jennifer Keegan
  • Lei Xu
    Key Laboratory of Biomedical Information Engineering of the Ministry of Education, Department of Biomedical Engineering, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, China.
  • Heye Zhang
    School of Biomedical Engineering, Sun Yat-sen University, Shenzhen, China.
  • Zhanming Fan
    From the Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 2nd Anzhen Road, Chaoyang District, Beijing, China (N.Z., L.X., Z.F.); Cardiovascular Research Centre, Royal Brompton Hospital, London, England (G.Y., R.S., J.K., D.F.); National Heart and Lung Institute, Imperial College London, London, England (G.Y., R.S., J.K., D.F.); Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China (Z.G., H.Z.); Anhui University, Hefei, China (C.X., Y.Z.); and School of Biomedical Engineering, Sun Yat-Sen University, Shenzhen, China (H.Z.).
  • David Firmin