Artificial intelligence detection of distal radius fractures: a comparison between the convolutional neural network and professional assessments.

Journal: Acta orthopaedica
PMID:

Abstract

Background and purpose - Artificial intelligence has rapidly become a powerful method in image analysis with the use of convolutional neural networks (CNNs). We assessed the ability of a CNN, with a fast object detection algorithm previously identifying the regions of interest, to detect distal radius fractures (DRFs) on anterior-posterior (AP) wrist radiographs. Patients and methods - 2,340 AP wrist radiographs from 2,340 patients were enrolled in this study. We trained the CNN to analyze wrist radiographs in the dataset. Feasibility of the object detection algorithm was evaluated by intersection of the union (IOU). The diagnostic performance of the network was measured by area under the receiver operating characteristics curve (AUC), accuracy, sensitivity, specificity, and Youden Index; the results were compared with those of medical professional groups. Results - The object detection model achieved a high average IOU, and none of the IOUs had a value less than 0.5. The AUC of the CNN for this test was 0.96. The network had better performance in distinguishing images with DRFs from normal images compared with a group of radiologists in terms of the accuracy, sensitivity, specificity, and Youden Index. The network presented a similar diagnostic performance to that of the orthopedists in terms of these variables. Interpretation - The network exhibited a diagnostic ability similar to that of the orthopedists and a performance superior to that of the radiologists in distinguishing AP wrist radiographs with DRFs from normal images under limited conditions. Further studies are required to determine the feasibility of applying our method as an auxiliary in clinical practice under extended conditions.

Authors

  • Kaifeng Gan
    a Department of Orthopaedics , Ningbo Medical Center, Lihuili Hospital , Ningbo , 315000 , China ;
  • Dingli Xu
    State Key Laboratory of Organ Failure Research, Department of Cardiology and; Department of Cardiology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China; Key Laboratory For Organ Failure Research, Ministry of Education of the People's Republic of China, Guangzhou, Guangdong, China. Electronic address: dinglixu@fimmu.com.
  • Yimu Lin
    c Department of Orthopaedics , Second Affiliated Hospital of Wenzhou Medical University , Wenzhou , 325027 , China ;
  • Yandong Shen
    a Department of Orthopaedics , Ningbo Medical Center, Lihuili Hospital , Ningbo , 315000 , China ;
  • Ting Zhang
    Beijing Municipal Key Laboratory of Child Development and Nutriomics, Capital Institute of Pediatrics, Beijing 100020, China.
  • Keqi Hu
    a Department of Orthopaedics , Ningbo Medical Center, Lihuili Hospital , Ningbo , 315000 , China ;
  • Ke Zhou
    School of Statistics at University of International Business and Economics, Beijing, China. Electronic address: 02417@uibe.edu.cn.
  • Mingguang Bi
    a Department of Orthopaedics , Ningbo Medical Center, Lihuili Hospital , Ningbo , 315000 , China ;
  • Lingxiao Pan
    a Department of Orthopaedics , Ningbo Medical Center, Lihuili Hospital , Ningbo , 315000 , China ;
  • Wei Wu
    Department of Pharmacy, The First Affiliated Hospital, Fujian Medical University, Fuzhou, China.
  • Yunpeng Liu
    e Faculty of Electronics & Computer , Zhejiang Wanli University , Ningbo , 315000 , China.