Comparison of Two-Port and Three-Port Approaches in Robotic Lobectomy for Non-Small Cell Lung Cancer.

Journal: World journal of surgery
Published Date:

Abstract

BACKGROUND: Robot-assisted lobectomy has been used to treat non-small cell lung cancer and usually uses 3 or 4 ports and 3 or 4 robotic arms. We recently developed a two-port approach for robotic lobectomy using three robotic arms and performed a propensity score-matched analysis to compare the feasibility of the two-port and three-port techniques.