Paper-based fluorescent immunoassay for highly sensitive and selective detection of norfloxacin in milk at picogram level.

Journal: Talanta
PMID:

Abstract

Norfloxacin (NOR) in milk may influence mammalian cell replication and bring about a decrease in the efficiency for treating infection in humans. However, current techniques for detecting NOR usually require expensive instruments and trained personnel. In this work, we have developed a low-cost and simple method via paper-based fluorescent immunoassay for highly sensitive and selective detection of NOR in milk at picogram level. The NOR monoclonal antibody labeled with quantum dots is used as a detection probe to recognize the corresponding NOR, which can quantitatively detect NOR on paper-based devices. The detection limits in aqueous solution and milk are 1 pg/mL and 10 pg/mL, respectively. The developed paper-based method provides a cheap, sensitive, eco-friendly, and rapid approach for quantitative detection of trace NOR in milk, which may find wide applications in food safety inspection. Noteworthy, the method is especially suitable for applications at resource-limited and on-site settings.

Authors

  • Lijun Zong
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Yucui Jiao
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Xueying Guo
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Chengxian Zhu
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Lei Gao
    Microscopy Core Facility, Biomedical Research Core Facilities, Westlake University, Hangzhou, China.
  • Yufeng Han
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Lin Li
    Department of Medicine III, LMU University Hospital, LMU Munich, Munich, Germany.
  • Chengwu Zhang
    Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (Nanjing Tech), 30 South Puzhu Road, Nanjing, 211816, P.R. China.
  • Zhipeng Liu
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Jinhua Liu
    Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China.
  • Qiang Ju
    Institute of Advanced Materials (IAM) & Key Laboratory of Flexible Electronics (KLOFE), Jiangsu National Synergetic Innovation Center for Advanced Materials (SICAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, PR China.
  • Hai-Dong Yu
    Key Laboratory of Flexible Electronics (KLOFE) and Institute of Advanced Materials (IAM), Nanjing Tech University (NanjingTech), 30 South Puzhu Road, Nanjing 211816, P. R. China.
  • Wei Huang
    Shaanxi Institute of Flexible Electronics, Northwestern Polytechnical University, 710072 Xi'an, China.