The evaluation of the reduction of radiation dose via deep learning-based reconstruction for cadaveric human lung CT images.

Journal: Scientific reports
Published Date:

Abstract

To compare the quality of CT images of the lung reconstructed using deep learning-based reconstruction (True Fidelity Image: TFI ā„¢; GE Healthcare) to filtered back projection (FBP), and to determine the minimum tube current-time product in TFI without compromising image quality. Four cadaveric human lungs were scanned on CT at 120 kVp and different tube current-time products (10, 25, 50, 75, 100, and 175 mAs) and reconstructed with TFI and FBP. Two image evaluations were performed by three independent radiologists. In the first experiment, using the same tube current-time product, a side-by-side TFI and FBP comparison was performed. Images were evaluated with regard to noise, streak artifacts, and overall image quality. Overall image quality was evaluated in view of whole image quality. In the second experiment, CT images reconstructed using TFI and FBP with five different tube current-time products were displayed in random order, which were evaluated with reference to the 175 mAs-FBP image. Images were scored with regard to normal structure, abnormal findings, noise, streak artifacts, and overall image quality. Median scores from three radiologists were statistically analyzed. Quantitative evaluation of noise was performed by setting regions of interest (ROIs) in air. In first experiment, overall image quality was improved, and noise was decreased in images of TFI compared to that of FBP for all tube current-time products. In second experiment, scores of all evaluation items except for small vessels in images of 25 mAs-TFI were almost the same as that of 175 mAs-FBP (all p > 0.31). Using TFI instead of FBP, at least 85% radiation dose reduction could be possible without any degradation in the image quality.

Authors

  • Tomo Miyata
    Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Masahiro Yanagawa
    Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
  • Noriko Kikuchi
    Department of Radiology, Osaka University Graduate School of Medicine.
  • Kazuki Yamagata
    Department of Artificial Intelligence Diagnostic Radiology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Yukihisa Sato
    Department of Radiology, Suita Municipal Hospital, 5-7 Kishibeshinmati, Suita-city, Osaka, 564-8567, Japan.
  • Yuriko Yoshida
    Department of Cardiovascular Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
  • Mitsuko Tsubamoto
    Department of Future Diagnostic Radiology, Graduate School of Medicine, Osaka University, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
  • Noriyuki Tomiyama
    Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.