Multicenter development of a deep learning radiomics and dosiomics nomogram to predict radiation pneumonia risk in non-small cell lung cancer.

Journal: Scientific reports
PMID:

Abstract

Radiation pneumonia (RP) is the most common side effect of chest radiotherapy, and can affect patients' quality of life. This study aimed to establish a combined model of radiomics, dosiomics, deep learning (DL) based on simulated location CT and dosimetry images combining with clinical parameters to improve the predictive ability of ≥ 2 grade RP (RP2) in patients with non-small cell lung cancer (NSCLC). This study retrospectively collected 245 patients with NSCLC who received radiotherapy from three hospitals. 162 patients from Hospital I were randomly divided into training cohort and internal validation cohort according to 7:3. 83 patients from two other hospitals served as an external validation cohort. Multivariate analysis was used to screen independent clinical predictors and establish clinical model (CM). The radiomic and dosiomics (RD) features and DL features were extracted from simulated location CT and dosimetry images based on the region of interest (ROI) of total lung-PTV (TL-PTV). The features screened by the t-test and least absolute shrinkage and selection operator (LASSO) were used to construct the RD and DL model, and RD-score and DL-score were calculated. RD-score, DL-score and independent clinical features were combined to establish deep learning radiomics and dosiomics nomogram (DLRDN). The model performance was evaluated by area under the curve (AUC). Three clinical factors, including V20, V30, and mean lung dose (MLD), were used to establish the CM. 7 RD features including 4 radiomics features and 3 dosiomics features were selected to establish RD model. 10 DL features were selected to establish DL model. Among the different models, DLRDN showed the best predictions, with the AUCs of 0.891 (0.826-0.957), 0.825 (0.693-0.957), and 0.801 (0.698-0.904) in the training cohort, internal validation cohort and external validation cohort, respectively. DCA showed that DLRDN had a higher overall net benefit than other models. The calibration curve showed that the predicted value of DLRDN was in good agreement with the actual value. Overall, radiomics, dosiomics, and DL features based on simulated location CT and dosimetry images have the potential to help predict RP2. The combination of multi-dimensional data produced the optimal predictive model, which could provide guidance for clinicians.

Authors

  • Xun Wang
    College of Computer Science and Technology, China University of Petroleum, Dongying, China.
  • Aiping Zhang
    Department of Radiation Oncology, Tumor Hospital of Jining, Jianshe North Road, Jining, 272123, Shandong, China.
  • Huipeng Yang
    Department of Radiation Oncology, Jining First People's Hospital, Jiankang Road, Jining, 272029, Shandong, China.
  • Guqing Zhang
    Department of Medical Imaging, Affiliated Hospital of Jining Medical University, Guhuai Road, Jining, 272000, Shandong, China.
  • Junli Ma
    Department of Radiation Oncology, Affiliated Hospital of Jining Medical University, Guhuai Road, Jining, 272000, Shandong, China.
  • Shucheng Ye
    Department of Radiation Oncology, Affiliated Hospital of Jining Medical University, Guhuai Road, Jining, 272000, Shandong, China.
  • Shuang Ge
    Shenzhen International Graduate School, Tsinghua University, 2279 Lishui Road, Nanshan District, Shenzhen 518055, Guangdong, China.