Assessment of the stability of citrate-buffered flucloxacillin for injection when stored in two commercially available ambulatory elastomeric devices: INfusor LV (Baxter) and Accufuser (Woo Young Medical): a study compliant with the NHS Yellow Cover Document (YCD) requirements.

Journal: European journal of hospital pharmacy : science and practice
PMID:

Abstract

OBJECTIVES: To investigate the effect of pH and buffers on the degradation rate of flucloxacillin and to determine if flucloxacillin can be stabilised using a buffered diluent for up to 14 days when stored at 2°C-8°C including a 24-hour infusion period at 32°C in two elastomeric devices (Accufuser and INfusor LV) filled to 240 mL. Testing as per the NHS Pharmaceutical Quality Assurance Committee Yellow Cover Document (YCD) requirements.