For image-guided small animal irradiations, the whole workflow of imaging, organ contouring, irradiation planning, and delivery is typically performed in a single session requiring continuous administration of anaesthetic agents. Automating contouring leads to a faster workflow, which limits exposure to anaesthesia and thereby, reducing its impact on experimental results and on animal wellbeing. Here, we trained the 2D and 3D U-Net architectures of no-new-Net (nnU-Net) for autocontouring of the thorax in mouse micro-CT images. We trained the models only on native CTs and evaluated their performance using an independent testing dataset (i.e., native CTs not included in the training and validation). Unlike previous studies, we also tested the model performance on an external dataset (i.e., contrast-enhanced CTs) to see how well they predict on CTs completely different from what they were trained on. We also assessed the interobserver variability using the generalized conformity index ([Formula: see text]) among three observers, providing a stronger human baseline for evaluating automated contours than previous studies. Lastly, we showed the benefit on the contouring time compared to manual contouring. The results show that 3D models of nnU-Net achieve superior segmentation accuracy and are more robust to unseen data than 2D models. For all target organs, the mean surface distance (MSD) and the Hausdorff distance (95p HD) of the best performing model for this task (nnU-Net 3d_fullres) are within 0.16 mm and 0.60 mm, respectively. These values are below the minimum required contouring accuracy of 1 mm for small animal irradiations, and improve significantly upon state-of-the-art 2D U-Net-based AIMOS method. Moreover, the conformity indices of the 3d_fullres model also compare favourably to the interobserver variability for all target organs, whereas the 2D models perform poorly in this regard. Importantly, the 3d_fullres model offers 98% reduction in contouring time.

Authors

  • Justin Malimban
    Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands. j.malimban@umcg.nl.
  • Danny Lathouwers
    Delft University of Technology, Department of Radiation Science and Technology, Mekelweg 15, Delft 2629JB, Netherlands.
  • Haibin Qian
    Department of Medical Biology, Amsterdam University Medical Centers (Location AMC) and Cancer Center Amsterdam, 1105 AZ, Amsterdam, The Netherlands.
  • Frank Verhaegen
    Department of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht, Netherlands. frank.verhaegen@maastro.nl.
  • Julia Wiedemann
    Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands.
  • Sytze Brandenburg
    Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, 9700 RB, Groningen, The Netherlands.
  • Marius Staring
    Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden PO Box 9600, 2300 RC, The Netherlands.