AIMC Topic: Mitral Valve

Clear Filters Showing 51 to 60 of 79 articles

Automatic Valve Plane Localization in Myocardial Perfusion SPECT/CT by Machine Learning: Anatomic and Clinical Validation.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine
Precise definition of the mitral valve plane (VP) during segmentation of the left ventricle for SPECT myocardial perfusion imaging (MPI) quantification often requires manual adjustment, which affects the quantification of perfusion. We developed a ma...

Prevention of Unilateral Pulmonary Edema Complicating Robotic Mitral Valve Operations.

The Annals of thoracic surgery
BACKGROUND: Unilateral pulmonary edema (UPE) has been reported after mitral operations performed through the right side of the chest. The clinical presentation is compatible with an ischemia-reperfusion injury. This report describes modifications to ...

Robotic Transcatheter Mitral Valve Replacement Using the Sapien XT in the Setting of Severe Mitral Annular Calcification.

Journal of cardiac surgery
We describe the use of the Sapien XT, placed in the mitral position using a totally endoscopic robotic approach in a 76-year-old man with extensive circumferential mitral calcifications and severe stenosis. The patient was at high risk for traditiona...

Robotic Mitral Valve Replacement in Pectus Excavatum.

Journal of cardiac surgery
Exposure of the mitral valve can be challenging using conventional sternotomy and thoracotomy incisions in patients with pectus deformity. We report the use of a robotic approach to replace a rheumatic mitral valve in a patient with pectus excavatum....

Beating Heart Minimally Invasive Mitral Valve Surgery in Patients With Patent Coronary Bypass Grafts.

The Canadian journal of cardiology
BACKGROUND: Redo mitral valve surgery in patients with patent coronary bypass grafts carries a risk of graft injury and postoperative bleeding. We compare early results of reoperative minimally invasive on-pump beating heart mitral valve surgery (OPB...

The Expanding Role of Endoscopic Robotics in Mitral Valve Surgery: 1,257 Consecutive Procedures.

The Annals of thoracic surgery
BACKGROUND: The role of robotic instruments in mitral valve (MV) surgery continues to evolve. The purpose of this study was to assess the safety, efficacy, and scope of MV surgery using a lateral endoscopic approach with robotics (LEAR) technique.

Identification of Mitral Annulus Hinge Point Based on Local Context Feature and Additive SVM Classifier.

Computational and mathematical methods in medicine
The position of the hinge point of mitral annulus (MA) is important for segmentation, modeling and multimodalities registration of cardiac structures. The main difficulties in identifying the hinge point of MA are the inherent noisy, low resolution o...

DeepValve: The first automatic detection pipeline for the mitral valve in Cardiac Magnetic Resonance imaging.

Computers in biology and medicine
Mitral valve (MV) assessment is key to diagnosing valvular disease and to addressing its serious downstream complications. Cardiac magnetic resonance (CMR) has become an essential diagnostic tool in MV disease, offering detailed views of the valve st...

Deep neural network valve detection for accelerometer based cardiac monitoring.

Scientific reports
Miniaturized accelerometers incorporated in pacing leads attached directly onto the heart provide a means for continuous monitoring of cardiac function. Several functional accelerometer indices first require detection of valve events. We previously d...