AIMC Topic: Patient Positioning

Clear Filters Showing 41 to 50 of 50 articles

Development of system using beam's eye view images to measure respiratory motion tracking errors in image-guided robotic radiosurgery system.

Journal of applied clinical medical physics
The accuracy of the CyberKnife Synchrony Respiratory Tracking System (SRTS) is considered to be patient-dependent because the SRTS relies on an individual correlation between the internal tumor position (ITP) and the external marker position (EMP), a...

Laparoscopic nephrectomy and partial nephrectomy: intraperitoneal, retroperitoneal, single site.

The Urologic clinics of North America
The indication for use of laparoscopy, in the pediatric population, was initially for diagnostic purposes. As confidence with the technology and utility grew, it began to be applied for therapeutic indications. With equivalent surgical outcomes and d...

Artificial Intelligence for Assessment of Digital Mammography Positioning Reveals Persistent Challenges.

Journal of breast imaging
OBJECTIVE: Mammographic breast cancer detection depends on high-quality positioning, which is traditionally assessed and monitored subjectively. This study used artificial intelligence (AI) to evaluate mammography positioning on digital screening mam...

Head-down tilt lithotomy position and well-leg compartment syndrome: An international survey of current practice.

Colorectal disease : the official journal of the Association of Coloproctology of Great Britain and Ireland
AIM: Well-leg compartment syndrome (WLCS) is a serious complication of prolonged surgery in the head-down tilt lithotomy (HDTL) position associated with increased postoperative morbidity and mortality. However, there is a lack of awareness and clinic...

PIAA: Pre-imaging all-round assistant for digital radiography.

Technology and health care : official journal of the European Society for Engineering and Medicine
BACKGROUND: In radiography procedures, radiographers' suboptimal positioning and exposure parameter settings may necessitate image retakes, subjecting patients to unnecessary ionizing radiation exposure. Reducing retakes is crucial to minimize patien...

Robot-assisted intrathoracic procedure for dumbbell tumour in the prone position.

Interactive cardiovascular and thoracic surgery
A 24-year-old man presented with a dumbbell-shaped right posterior mediastinal mass. The patient was placed in the prone position following general anaesthesia and intubation. After laminectomy and dissection of the dorsal part of the tumour using a ...

Modeling and performance evaluation of a robotic treatment couch for tumor tracking.

Biomedizinische Technik. Biomedical engineering
Tumor motion during radiation therapy increases the irradiation of healthy tissue. However, this problem may be mitigated by moving the patient via the treatment couch such that the tumor motion relative to the beam is minimized. The treatment couch ...

Commissioning of a proton gantry equipped with dual x-ray imagers and a robotic patient positioner, and evaluation of the accuracy of single-beam image registration for this system.

Medical physics
PURPOSE: To check the accuracy of a gantry equipped with dual x-ray imagers and a robotic patient positioner for proton radiotherapy, and to evaluate the accuracy and feasibility of single-beam registration using the robotic positioner.

Concepts in creating an evidence-based anesthetic protocol for robot-assisted laparoscopic pelvic surgery.

The Journal of medical practice management : MPM
BACKGROUND: Robotic-assisted surgery has increased in popularity in recent years. Benefits have been observed for both the patient and hospital system as the technology shifts surgery from the open to the laparoscopic arena. Some of the advantages of...