Low bioavailability and high binding affinity to plasma proteins led to the difficulty for the quantitative detection of lithospermate B (LSB) in plasma. This study aimed to develop a protocol for detecting LSB in plasma. A method was employed to qua...
Natural product chemistry began in Reims, France, in a pharmacognosy research laboratory whose main emphasis was the isolation and identification of bioactive molecules, following the guidelines of chemotaxonomy. The structure elucidation of new comp...
While the biological function of the 3α epimer of 25-hydroxyvitamin D (25(OH)D) remains unknown, its presence needs to be accurately captured and separated from the main 3β epimer, to avoid positive bias in vitamin D status analyses. Several recent L...
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Dec 28, 2016
An accurate, precise, selective, and sensitive liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of imperatorin (IMP) and its metabolite, xanthotoxol (XAN), in rat plasma and ...
Journal of pharmaceutical and biomedical analysis
Dec 23, 2016
An LC-MS/MS method was developed for the determination of digitoxigenin in mice skin samples. Chromatographic separation was achieved on an Agilent Poroshell 120 EC-C18 column. Mass spectrometric detection was achieved by a triple-quadrupole mass spe...
UNLABELLED: Mucopolysaccharidoses (MPSs) and mucolipidoses (ML) are groups of lysosomal storage disorders in which lysosomal hydrolases are deficient leading to accumulation of undegraded glycosaminoglycans (GAGs), throughout the body, subsequently r...
Graphene oxide (GO) and carboxylated GO were used as labels for lateral flow immunoassays, instead of the conventionally used colloidal gold and colored latex labels. A sensor is demonstrated that enables fast screening for aflatoxin B (AFB) as a mod...
Stability-indicating LC methods using a UV detector and a charged aerosol detector (CAD) simultaneously were validated for the assessment of alogliptin (ALG) in tablets. The analysis was performed on a C8 column (250 × 4.6 mm, 5 μm) at a flow of 0.8 ...
A new green micellar liquid chromatographic method was developed and validated for the quantitative estimation of nicotinamide (NICO) and clindamycin phosphate (CLD) in bulk and pharmaceutical gel formulation. The analytes are well resolved in less t...
Journal of agricultural and food chemistry
Nov 28, 2016
Deoxynivalenol (DON) exposure is estimated by the combined measures of urinary DON and DON-glucuronides. In this study, data from single-mycotoxin (SM) and a multimycotoxin (MM) methods were compared for 256 Swedish adult urine samples. Both methods ...