AI Medical Compendium Topic

Explore the latest research on artificial intelligence and machine learning in medicine.

Fluoroscopy

Showing 71 to 80 of 111 articles

Clear Filters

Catheter Ablation of Focal Atrial Tachycardia Using Remote Magnetic Navigation.

The Journal of invasive cardiology
OBJECTIVES: The outcomes of catheter ablation in focal atrial tachycardia (AT) using remote magnetic navigation (RMN) are still controversial. The objectives of this study were to assess the acute and long-term outcomes of catheter ablation in focal ...

Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.

Medical physics
PURPOSE: This work aims to generate cine CT images (i.e., 4D images with high-temporal resolution) based on a novel principal component reconstruction (PCR) technique with motion learning from 2D fluoroscopic training images.

Deep architecture neural network-based real-time image processing for image-guided radiotherapy.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
INTRODUCTION: To develop real-time image processing for image-guided radiotherapy, we evaluated several neural network models for use with different imaging modalities, including X-ray fluoroscopic image denoising.

Robotic distal locking of intramedullary nailing: Technical description and cadaveric testing.

The international journal of medical robotics + computer assisted surgery : MRCAS
Interlocked intramedullary nailing is the treatment of choice for femoral shaft fractures. However, distal locking is a technically challenging part of the procedure that can result in distal femoral malrotation and high radiation exposure. We have t...

Computer vision-based diameter maps to study fluoroscopic recordings of small intestinal motility from conscious experimental animals.

Neurogastroenterology and motility
BACKGROUND: When available, fluoroscopic recordings are a relatively cheap, non-invasive and technically straightforward way to study gastrointestinal motility. Spatiotemporal maps have been used to characterize motility of intestinal preparations in...

Substantial superiority of Niobe ES over Niobe II system in remote-controlled magnetic pulmonary vein isolation.

International journal of cardiology
BACKGROUND: Catheter ablation of atrial fibrillation (AFib) primarily relies upon pulmonary vein isolation (PVI), but such procedures are associated with significant X-ray exposure. The newer Epoch system has been developed so as to enable more preci...

Partial displacement of epidural catheter after patient position change: A case report.

Journal of clinical anesthesia
Epidural catheter migration is a well-known cause of failed anesthesia and complications. One of the factors that affect catheter movement is when patients change their position after skin fixation. We report a case of an epidural catheter placed wit...

First-in-human robotic percutaneous coronary intervention for unprotected left main stenosis.

Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
The safety and feasibility of robotically-assisted percutaneous coronary intervention (PCI) for simple coronary lesions has been demonstrated. The CorPath robotic system (Corpath 200, Corindus, Waltham, MA) consists of a robotic arm mounted on the ca...

Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation.

Clinical research in cardiology : official journal of the German Cardiac Society
BACKGROUND: Long-term results after circumferential pulmonary vein isolation (CPVI) for the treatment of paroxysmal atrial fibrillation (PAF) using a robotic navigation system (RNS) have not yet been reported.

The impact of precise robotic lesion length measurement on stent length selection: ramifications for stent savings.

Cardiovascular revascularization medicine : including molecular interventions
BACKGROUND/PURPOSE: Coronary stent deployment outcomes can be negatively impacted by inaccurate lesion measurement and inappropriate stent length selection (SLS). We compared visual estimate of these parameters to those provided by the CorPath 200® R...