Restoration of the communication between brain circuitry is a crucial step in the recovery of brain damage induced by traumatic injuries or neurological insults. In this work we present a study of real-time unidirectional communication between a spik...
OBJECTIVE: Artificial manipulation of animal movement could offer interesting advantages and potential applications using the animal's inherited superior sensation and mobility. Although several behavior control models have been introduced, they gene...
Area V4 is the first object-specific processing stage in the ventral visual pathway, just as area MT is the first motion-specific processing stage in the dorsal pathway. For almost 50 years, coding of object shape in V4 has been studied and conceived...
Zhonghua er bi yan hou tou jing wai ke za zhi = Chinese journal of otorhinolaryngology head and neck surgery
33036510
To evaluate the safety and outcomes of robot-assisted electrode insertion in cochlear implantation. We first reported the case of robot-assisted electrode insertion of cochlear implantation in October 2019. A new slim electrode array of Nurotron co...
BACKGROUND: Robotics in neurosurgery has demonstrated widening indications and rapid growth in recent years. Robotic precision and reproducibility are especially pertinent to the field of functional neurosurgery. Deep brain stimulation (DBS) requires...
BACKGROUND: Deep brain stimulation (DBS) is an effective surgical technique used to ameliorate the motor symptoms associated with Parkinson's disease. One of the key elements that determine successful patient outcomes is the accurate positioning of t...
AIM: To explore the difference between robot assisted (RA) and stereotactic frame based (SF) stereoelectroencephalography (SEEG) in patients with medically refractory epilepsy.
BACKGROUND: The pursuit of improved accuracy for localization and electrode implantation in deep brain stimulation (DBS) and stereoelectroencephalography (sEEG) has fostered an abundance of disparate surgical/stereotactic practices. Specific practice...
Advancements in electrode design have resulted in micro-electrode arrays with hundreds of channels for single cell recordings. In the resulting electrophysiological recordings, each implanted electrode can record spike activity (SA) of one or more ne...
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
33306661
OBJECTIVE: To describe the first cochlear array insertions using a robot-assisted technique, with different types of straight or precurved electrode arrays, compared with arrays manually inserted into the cochlea.